01850nas a2200109 4500008004100000245005500041210005500096260005500151300000700206520148200213856004501695 1998 eng d00aExperience with the SZOTE PACS Starting Operations0 aExperience with the SZOTE PACS Starting Operations aBudapestbMagyar Radiológus TársaságcJune 1998 a683 a
Introduction: During the last four years a Picture Archiving andCommunication System (PACS) has been developed in the University mainly for educational purposes. The original intention was to use the system as a non-stop routine PACS, so the images of the modalities of the system should be available to the workstations connected to the University network at the different clinics. Material and method: Two CTs, one MR, one ultrasound, three fluoroscopy devices, two SPECTs, two gamma cameras and one X-ray film scanner have been connected to the computer network at SZOTE. One Silicon Graphics Challenge DM central image server collects the images and related data. The picture archiving and communication is DICOM conform. An ORACLE data management system facilitates the data retrieval. Step by step testing of the operation of the system began with the transport, conversion and archiving of images of two CTs, one MR and one SPECT: Results: The daily archiving of about 5000 images on 80-100 patients gradually demonstrated the slight incompatibility of DICOM or Interfile of the image modalities or converter stations and the minor shortcomings of the software. Three educational cabinets have been installed, in which the practical teaching of radiology has been performed since 1996. Discussion/conclusion: Full automatization is necessary for handling such huge amount of images. For this the PACS and RIS/HIS connection was needed which was successed as well.
uhttps://www.inf.u-szeged.hu/en/node/135701850nas a2200109 4500008004100000245005500041210005500096260005500151300000700206520148200213856004501695 1998 eng d00aExperience with the SZOTE PACS Starting Operations0 aExperience with the SZOTE PACS Starting Operations aBudapestbMagyar Radiológus TársaságcJune 1998 a683 aIntroduction: During the last four years a Picture Archiving andCommunication System (PACS) has been developed in the University mainly for educational purposes. The original intention was to use the system as a non-stop routine PACS, so the images of the modalities of the system should be available to the workstations connected to the University network at the different clinics. Material and method: Two CTs, one MR, one ultrasound, three fluoroscopy devices, two SPECTs, two gamma cameras and one X-ray film scanner have been connected to the computer network at SZOTE. One Silicon Graphics Challenge DM central image server collects the images and related data. The picture archiving and communication is DICOM conform. An ORACLE data management system facilitates the data retrieval. Step by step testing of the operation of the system began with the transport, conversion and archiving of images of two CTs, one MR and one SPECT: Results: The daily archiving of about 5000 images on 80-100 patients gradually demonstrated the slight incompatibility of DICOM or Interfile of the image modalities or converter stations and the minor shortcomings of the software. Three educational cabinets have been installed, in which the practical teaching of radiology has been performed since 1996. Discussion/conclusion: Full automatization is necessary for handling such huge amount of images. For this the PACS and RIS/HIS connection was needed which was successed as well.
uhttps://www.inf.u-szeged.hu/en/node/109200329nas a2200097 4500008004100000245005500041210005400096260002400150300001200174856004500186 1998 eng d00aExperience with the SZOTE-PACS Starting Operations0 aExperience with the SZOTEPACS Starting Operations aBarcelonacOct 1998 a43 - 44 uhttps://www.inf.u-szeged.hu/en/node/102700329nas a2200097 4500008004100000245005500041210005400096260002400150300001200174856004500186 1998 eng d00aExperience with the SZOTE-PACS Starting Operations0 aExperience with the SZOTEPACS Starting Operations aBarcelonacOct 1998 a43 - 44 uhttps://www.inf.u-szeged.hu/en/node/131101705nas a2200109 4500008004100000245004100041210004000082260005500122300000700177520136600184856004501550 1998 eng d00aImage Presentation in the SZOTE-PACS0 aImage Presentation in the SZOTEPACS aBudapestbMagyar Radiológus TársaságcJune 1998 a563 aThe SZOTE Picture Archiving and Communication System (SZOTEPACS) is used for: - teaching graduate and postgraduate students - picture archiving for scientific purposes - archiving and consulting data from radiological and nuclear medicine examinations In order to implement these tasks, archiving is not enough; it is also necessary to display images in various clinics and departments. On the basis of the cost/benefit principle, after an appropriate selection, Silicon Graphics workstations (Indy Modeler R5000PC microprocessor, 32 MB RM, 1 GB disc, 17”/8 bit color monitor) and Albacom Activa Standard computers (Intel Pentium 200 Mhz CPU, 32 MB EDO RAM, 2.1 GB disc, 17” GoldStar 78i color monitor) were implemented into the system. The problem of a relatively easy and fast search in the PACS image database is solved, if access is granted. The images are transferred to the workstations (viewing stations) in DICOM 3.0 format. The images processing program OSIRIS is suitable for the processing of images in DICOM format. The resolution of the viewing station display is: Silicon Graphics 1280 x 1024 x 8 bit; Albacom 1600 x 1200 x 8 bit. For the matrix specified above, the 256 grey scale is suitable for display of the chosen images in good quality, consultation with clinicians, and the comparison of control examinations with previous ones.
uhttps://www.inf.u-szeged.hu/en/node/131601705nas a2200109 4500008004100000245004100041210004000082260005500122300000700177520136600184856004501550 1998 eng d00aImage Presentation in the SZOTE-PACS0 aImage Presentation in the SZOTEPACS aBudapestbMagyar Radiológus TársaságcJune 1998 a563 aThe SZOTE Picture Archiving and Communication System (SZOTEPACS) is used for: - teaching graduate and postgraduate students - picture archiving for scientific purposes - archiving and consulting data from radiological and nuclear medicine examinations In order to implement these tasks, archiving is not enough; it is also necessary to display images in various clinics and departments. On the basis of the cost/benefit principle, after an appropriate selection, Silicon Graphics workstations (Indy Modeler R5000PC microprocessor, 32 MB RM, 1 GB disc, 17”/8 bit color monitor) and Albacom Activa Standard computers (Intel Pentium 200 Mhz CPU, 32 MB EDO RAM, 2.1 GB disc, 17” GoldStar 78i color monitor) were implemented into the system. The problem of a relatively easy and fast search in the PACS image database is solved, if access is granted. The images are transferred to the workstations (viewing stations) in DICOM 3.0 format. The images processing program OSIRIS is suitable for the processing of images in DICOM format. The resolution of the viewing station display is: Silicon Graphics 1280 x 1024 x 8 bit; Albacom 1600 x 1200 x 8 bit. For the matrix specified above, the 256 grey scale is suitable for display of the chosen images in good quality, consultation with clinicians, and the comparison of control examinations with previous ones.
uhttps://www.inf.u-szeged.hu/en/node/103301628nas a2200109 4500008004100000245003200041210003100073260005500104300000700159520130700166856004501473 1998 eng d00aStructure of the SZOTE-PACS0 aStructure of the SZOTEPACS aBudapestbMagyar Radiológus TársaságcJune 1998 a673 aIntroduction: The progress in computer techniques has resultedin the digital archivation and transport of images of radiology and nuclear medicine without loss of information. The images and image series produced by various image modalities are converted to a uniform image format, which provides their interconnectivity and interoperability. The image transport is very important at hospitals comprising pavilion systems. Material and method: Through the computer network of the SZOTE Picture Archiving and Communication System (SZOTE PACS) serves the radiology education with the aid of computer displays. Result: ATM network devices allow the fast transfer of images. Silicon Graphics and PC viewing stations provide fast image processing and presentation. Use of the DICOM standards in SZOTE PACS permits the development of teleradiology services. Discussion: The hardware structure and the parameters of the system will be presented in detail. The PACS is connected to the Radiology Information System of the Department of Radiology and the Department of Nuclear Medicine. Conclusion: This makes automatic image archiving possible. The system is user-friendly: it can be handled with minimum computer knowledge. A group has been established at the University to perform the PACS management.
uhttps://www.inf.u-szeged.hu/en/node/131501628nas a2200109 4500008004100000245003200041210003100073260005500104300000700159520130700166856004501473 1998 eng d00aStructure of the SZOTE-PACS0 aStructure of the SZOTEPACS aBudapestbMagyar Radiológus TársaságcJune 1998 a673 aIntroduction: The progress in computer techniques has resultedin the digital archivation and transport of images of radiology and nuclear medicine without loss of information. The images and image series produced by various image modalities are converted to a uniform image format, which provides their interconnectivity and interoperability. The image transport is very important at hospitals comprising pavilion systems. Material and method: Through the computer network of the SZOTE Picture Archiving and Communication System (SZOTE PACS) serves the radiology education with the aid of computer displays. Result: ATM network devices allow the fast transfer of images. Silicon Graphics and PC viewing stations provide fast image processing and presentation. Use of the DICOM standards in SZOTE PACS permits the development of teleradiology services. Discussion: The hardware structure and the parameters of the system will be presented in detail. The PACS is connected to the Radiology Information System of the Department of Radiology and the Department of Nuclear Medicine. Conclusion: This makes automatic image archiving possible. The system is user-friendly: it can be handled with minimum computer knowledge. A group has been established at the University to perform the PACS management.
uhttps://www.inf.u-szeged.hu/en/node/103202030nas a2200121 4500008004100000245014700041210007300188260003200261300001400293490009900307520145700406856004501863 1996 eng d00aOrvosi információs rendszerek a Szent-Györgyi Albert Orvostudományi Egyetemen: RIS, HIS és PACS. Információcsere a rendszerek között.0 aOrvosi információs rendszerek a SzentGyörgyi Albert Orvostudomán aBudapestbNJSZTc1996.11.14 a184 - 1860 vA számítástechnika orvosi és biológiai alkalmazásai: A XX. Neumann Kollokvium Kiadványa3 aRadiológiával kapcsolatos szöveges és képi információkatEgyetemünkön több autonóm információs rendszer kezel. Ilyen az egészségügyi szolgáltatásokkal összefüggő adminisztratív és klinikai információk szervezésére szolgáló kórházi információs rendszer (HIS), a radiológiai szolgáltatásokat kezelő információs rendszer (RIS) és a digitális képtovábbító, képtároló és visszakereső rendszer (PACS). A rendszerek közötti információcsere sarkalatos probléma. A RIS- ből információt kell átvenni a PCS-ba. A HIS rendeléseinek számítógépes kezelése szükségessé teszi a RIS-hez történő kapcsolat kialakítását. A RIS és a PACS között egy ut. SQL gateway biztosítja az információcserét. A gateway program figyeli a UNIX alapú képszerverről szövegfájlban jövő szabványos SQL kéréseket, továbbítja a RIS Novell szervere felé és a lekérdezés eredményét visszaküldi. A RIS és HIS közötti gateway program az AS400 és RIS szerver között tartja a kapcsolatot, az információcsere DBF fájlok segítségével folyik. Végleges megoldást csak a szabványosítás hozhat. Az általunk fejlesztett PACS már DICOM konform, dolgozunk a RIS DICOM konformmá tételén. Mivel a DICOm tartalmazza a képalkotó berendezések, a PACS és a HIS/RIS kapcsolatot leíró szabványt, alkalmazása lehetővé teszi a rendszerek közötti közvetlen információcserét.
uhttps://www.inf.u-szeged.hu/en/node/132901917nas a2200109 4500008004100000245014700041210007300188260003000261300001400291520145700305856004501762 1996 eng d00aOrvosi információs rendszerek a Szent-Györgyi Albert Orvostudományi Egyetemen: RIS, HIS és PACS. Információcsere a rendszerek között.0 aOrvosi információs rendszerek a SzentGyörgyi Albert Orvostudomán aBudapestbNJSZTcNov 1996 a184 - 1863 aRadiológiával kapcsolatos szöveges és képi információkatEgyetemünkön több autonóm információs rendszer kezel. Ilyen az egészségügyi szolgáltatásokkal összefüggő adminisztratív és klinikai információk szervezésére szolgáló kórházi információs rendszer (HIS), a radiológiai szolgáltatásokat kezelő információs rendszer (RIS) és a digitális képtovábbító, képtároló és visszakereső rendszer (PACS). A rendszerek közötti információcsere sarkalatos probléma. A RIS- ből információt kell átvenni a PCS-ba. A HIS rendeléseinek számítógépes kezelése szükségessé teszi a RIS-hez történő kapcsolat kialakítását. A RIS és a PACS között egy ut. SQL gateway biztosítja az információcserét. A gateway program figyeli a UNIX alapú képszerverről szövegfájlban jövő szabványos SQL kéréseket, továbbítja a RIS Novell szervere felé és a lekérdezés eredményét visszaküldi. A RIS és HIS közötti gateway program az AS400 és RIS szerver között tartja a kapcsolatot, az információcsere DBF fájlok segítségével folyik. Végleges megoldást csak a szabványosítás hozhat. Az általunk fejlesztett PACS már DICOM konform, dolgozunk a RIS DICOM konformmá tételén. Mivel a DICOm tartalmazza a képalkotó berendezések, a PACS és a HIS/RIS kapcsolatot leíró szabványt, alkalmazása lehetővé teszi a rendszerek közötti közvetlen információcserét.
uhttps://www.inf.u-szeged.hu/en/node/1042